NoShok 25 Series sanitary pressure transmitter is designed specifically for heavy-duty applications in the food and beverage industry where high accuracy, shock resistance and durability are required. The transmitter features pressure and temperature sensors mounted directly behind the diaphragm, which minimizes fill fluid, allows the use of a smaller diaphragm, and reduces the potential for damage. This provides active temperature compensation at the point of measurement to minimize temperature and position error. Diaphragms are laser-welded and helium leak-tested.
SERIES | 254 | |||
TRI-CLAMP SIZE | 12 | 1-1/2″ | 24 | 3″ |
16 | 2″ | |||
PRESSURE RANGES (Adjustable)* |
40inH2O-vac | -40 inH20 to 0 inH2O* | 16/40 inH2O | 0 inH2O to 16 inH2O to 0 inH2O to 40 inH2O (.6 psig to 1.45 psig) |
160inH2O-vac | -160inH2O to 0 inH2O | 40/160 inH2O | 0 inH2O to 40 inH2O to 0 inH2O to 160 inH2O (1.45 psig to 5.8 psig) | |
14.7/43-vac | -14.7 psig to 43 psig | 160/637 inH2O | 0 inH2O to 160 inH2O to 0 inH2O to 637 inH2O (5.8 psig to 23 psig) | |
14.7/130-vac | -14.7 psig to 130 psig | 14.5/58 | 14.5 psig to 58 psig (0 inH2O to 400 inH2O to 0 inH2O to 1,607 inH2O) | |
14.7/335-vac | -14.7 to 335 psig | 29/145 | 29 psig to 145 psig (0 inH2O to 803 inH2O to 0 inH2O to 4,017 inH2O) | |
14.7/1145-vac | -14.7 psig to 1145 psig | 87/350 | 87 psig to 350 psig (0 inH2O to 2,410 inH2O to 0 inH2O to 9,697 inH2O) | |
290/1160 | 290 psig to 1,160 psig (0 inH2O to 8,035 inH2O to 0 inH2O to 32,140 inH2O) | |||
ACCURACIES | 1 | 0.2% of adjusted span | ||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 43 | 4 mA to 20 mA, 2-wire and Hart® signal |
ELECTRICAL CONNECTIONS |
25 | M12 x 1 (4-pin) | 71 | PG9 Cable Gland |
28 | 1/2” NPT Female | |||
OPTIONS | TC | Transparent Cover (for display) |
NoShok 25 Series sanitary pressure transmitter is designed specifically for heavy-duty applications in the food and beverage industry where high accuracy, shock resistance and durability are required. The transmitter features pressure and temperature sensors mounted directly behind the diaphragm, which minimizes fill fluid, allows the use of a smaller diaphragm, and reduces the potential for damage. This provides active temperature compensation at the point of measurement to minimize temperature and position error. Diaphragms are laser-welded and helium leak-tested.
SERIES | 254 | |||
TRI-CLAMP SIZE | 12 | 1-1/2″ | 24 | 3″ |
16 | 2″ | |||
PRESSURE RANGES (Adjustable)* |
40inH2O-vac | -40 inH20 to 0 inH2O* | 16/40 inH2O | 0 inH2O to 16 inH2O to 0 inH2O to 40 inH2O (.6 psig to 1.45 psig) |
160inH2O-vac | -160inH2O to 0 inH2O | 40/160 inH2O | 0 inH2O to 40 inH2O to 0 inH2O to 160 inH2O (1.45 psig to 5.8 psig) | |
14.7/43-vac | -14.7 psig to 43 psig | 160/637 inH2O | 0 inH2O to 160 inH2O to 0 inH2O to 637 inH2O (5.8 psig to 23 psig) | |
14.7/130-vac | -14.7 psig to 130 psig | 14.5/58 | 14.5 psig to 58 psig (0 inH2O to 400 inH2O to 0 inH2O to 1,607 inH2O) | |
14.7/335-vac | -14.7 to 335 psig | 29/145 | 29 psig to 145 psig (0 inH2O to 803 inH2O to 0 inH2O to 4,017 inH2O) | |
14.7/1145-vac | -14.7 psig to 1145 psig | 87/350 | 87 psig to 350 psig (0 inH2O to 2,410 inH2O to 0 inH2O to 9,697 inH2O) | |
290/1160 | 290 psig to 1,160 psig (0 inH2O to 8,035 inH2O to 0 inH2O to 32,140 inH2O) | |||
ACCURACIES | 1 | 0.2% of adjusted span | ||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 43 | 4 mA to 20 mA, 2-wire and Hart® signal |
ELECTRICAL CONNECTIONS |
25 | M12 x 1 (4-pin) | 71 | PG9 Cable Gland |
28 | 1/2” NPT Female | |||
OPTIONS | TC | Transparent Cover (for display) |