Noshok 615-2-1-1-8-6 Pressure Transmitter, 0 psig to 2 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/2 NPT Male, 1/2 NPT Conduit w/ 36 in Cable Attached

Part Number: 615-2-1-1-8-6 Tag:

Original price was: $759.53.Current price is: $607.62.

19 People watching this product now!

Pressure Transmitter, 0 psig to 2 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/2 NPT Male, 1/2 NPT Conduit w/ 36 in Cable Attached

615 & 616 Series High Accuracy Heavy-Duty Pressure Transducers

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire;
0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, 1 Vdc to 5 Vdc, 3-wire
Pressure ranges Vacuum through 0 psig to 145,000 psig
Absolute from 0 psia to 15 psia through 0 psia to 300 psia
Accuracy ± 0.25% full scale (BFSL); optional ± 0.125% full scale (BFSL); (includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale for 1 year, non-accumulating
Adjustment ± 10% full scale for zero and span
Response time Less than 1 ms (between 10% and 90% full scale)
Service life >100,000,000 load cycles
Temperature ranges Compensated 32 °F to 175 °F (0 °C to 80 °C)
Effect ± 0.01%/ °F for zero and span
Media -20 °F to 212 °F (-30 °C to 100 °C)
Ambient -15 °F to 175 °F (-10 °C to 80 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire,
0 Vdc to 5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc, 3-wire)
Load limitations ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA
≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire
≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire
Proof pressure 3 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi
1.2 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Burst pressure 3.8 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
1.5 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Measuring element 316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel for ≥500 psi
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating IP65
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, overvoltage and short circuit protection
Shock 1,000 g’s according to IEC 60068-2-27
Vibration 15 g’s according to IEC 60068-2-6
Weight Approximately 7.2 oz.
 

Reviews

There are no reviews yet.

Be the first to review “Noshok 615-2-1-1-8-6 Pressure Transmitter, 0 psig to 2 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/2 NPT Male, 1/2 NPT Conduit w/ 36 in Cable Attached”

Your email address will not be published. Required fields are marked *

Description

Pressure Transmitter, 0 psig to 2 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/2 NPT Male, 1/2 NPT Conduit w/ 36 in Cable Attached

615 & 616 Series High Accuracy Heavy-Duty Pressure Transducers

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire;
0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, 1 Vdc to 5 Vdc, 3-wire
Pressure ranges Vacuum through 0 psig to 145,000 psig
Absolute from 0 psia to 15 psia through 0 psia to 300 psia
Accuracy ± 0.25% full scale (BFSL); optional ± 0.125% full scale (BFSL); (includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale for 1 year, non-accumulating
Adjustment ± 10% full scale for zero and span
Response time Less than 1 ms (between 10% and 90% full scale)
Service life >100,000,000 load cycles
Temperature ranges Compensated 32 °F to 175 °F (0 °C to 80 °C)
Effect ± 0.01%/ °F for zero and span
Media -20 °F to 212 °F (-30 °C to 100 °C)
Ambient -15 °F to 175 °F (-10 °C to 80 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire,
0 Vdc to 5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc, 3-wire)
Load limitations ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA
≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire
≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire
Proof pressure 3 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi
1.2 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Burst pressure 3.8 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
1.5 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Measuring element 316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel for ≥500 psi
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating IP65
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, overvoltage and short circuit protection
Shock 1,000 g’s according to IEC 60068-2-27
Vibration 15 g’s according to IEC 60068-2-6
Weight Approximately 7.2 oz.