Showing all 2 results

200-600-2-5-3-1-CC Pressure Transmitter, 0 psig to 600 psig, 0.25% Accuracy (BFSL), 0 Vdc to 10 Vdc Output, SAE J1926-3:7/16-20 Adjustable, Mini-Hirschmann w/ 36 in Cable Attached, Certified Calibration

In stock

Original price was: $802.28.Current price is: $641.20.
Add to cart
SKU: 200-600-2-5-3-1-CC

200-600-2-5-3-6-CC Pressure Transmitter, 0 psig to 600 psig, 0.25% Accuracy (BFSL), 0 Vdc to 10 Vdc Output, SAE J1926-3:7/16-20 Adjustable, 1/2 NPT Conduit w/ 36 in Cable Attached, Certified Calibration

In stock

Original price was: $911.84.Current price is: $728.00.
Add to cart
SKU: 200-600-2-5-3-6-CC

Voltage Output Pressure Transducer-600 PSI

  • Ranges from vacuum to 0 psig to 15,000 psig; absolute ranges from 0 psia to 15 psia through 0 psia to 300 psia
  • Voltage output
  • 316 and 17-4PH Stainless Steel wetted parts
  • CE compliant to suppress RFI, EMI and ESD
  • Ideal for applications including HVAC, hydraulics & pneumatics, injection molding machines, railroad equipment and stamping & forming presses
  • SPECIFICATIONS
    Output signals 0 Vdc to 5 Vdc, 3-wire; 0 Vdc to 10 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
    1 Vdc to 6 Vdc, 3-wire; 1 Vdc to 11 Vdc, 3-wire
    Pressure ranges Vacuum through 0 psig to 15,000 psig
    Absolute from 0 psia to 15 psia through 0 psia to 300 psia
    Accuracy ñ0.5% full scale (BFSL); optional ñ0.25% full scale (BFSL);
    (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
    Stability ó ñ0.2% full scale per year, non-accumulating
    Adjustment ñ10% full scale for zero and span
    Response time ó 1 ms (between 10% and 90% full scale)
    Pressure cycle limit ó 1 ms (between 10% and 90% full scale)
    Service life > 100,000,000 load cycles
    Temperature ranges Compensated 32 øF to 176 øF (0 øC to 80 øC)
    Effect ñ0.017% full scale/ øF for zero and span
    Media -22 øF to 212 øF (-30 øC to 100 øC)
    Ambient -40 øF to 185 øF (-40 øC to 85 øC)
    Storage -40 øF to 212 øF (-40 øC to 100 øC)
    Power requirement* 10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire,
    1 Vdc to 6 Vdc, 3-wire)
    14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc, 3-wire)
    Load limitations ò 5,000 ê for 0 Vdc to 5 Vdc, 1 Vdc to 5 Vdc, and 1 Vdc to 6 Vdc outputs;
    ò10,000 ê for 0 Vdc to 10 Vdc and 1 Vdc to 11 Vdc outputs.
    Current consumption 8 mA
    Proof pressure 3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
    1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
    1.5 times full scale for 0 psi to 15,000 psi
    Burst pressure 3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
    4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
    3 times full scale for 0 psi to 15,000 psi
    Measuring element 316 stainless steel for vacuum through 300 psi;
    17-4PH stainless steel for ò500 psi
    Connection 316 stainless steel
    Housing material 316 stainless steel
    Environmental rating IP65
    Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
    RFI, EMI and ESD protection
    Electrical protection Reverse polarity, over-voltage and short circuit protection
    Shock 1,000 g?s according to IEC 60068-2-27
    Vibration 20 g?s according to IEC 60068-2-6
    Weight Approximately 3.5 oz.