SPECIFICATIONS
Output signals 0 Vdc to 5 Vdc, 3-wire; 0 Vdc to 10 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
1 Vdc to 6 Vdc, 3-wire; 1 Vdc to 11 Vdc, 3-wire
Pressure ranges Vacuum through 0 psig to 15,000 psig
Absolute from 0 psia to 15 psia through 0 psia to 300 psia
Accuracy ±0.5% full scale (BFSL); optional ±0.25% full scale (BFSL);
(Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale per year, non-accumulating
Adjustment ±10% full scale for zero and span
Response time ≤ 1 ms (between 10% and 90% full scale)
Pressure cycle limit ≤ 1 ms (between 10% and 90% full scale)
Service life > 100,000,000 load cycles
Temperature ranges Compensated 32 °F to 176 °F (0 °C to 80 °C)
Effect ±0.017% full scale/ °F for zero and span
Media -22 °F to 212 °F (-30 °C to 100 °C)
Ambient -40 °F to 185 °F (-40 °C to 85 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire,
1 Vdc to 6 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc, 3-wire)
Load limitations ≥ 5,000 Ω for 0 Vdc to 5 Vdc, 1 Vdc to 5 Vdc, and 1 Vdc to 6 Vdc outputs;
≥10,000 Ω for 0 Vdc to 10 Vdc and 1 Vdc to 11 Vdc outputs.
Current consumption 8 mA
Proof pressure 3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi
Burst pressure 3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
Measuring element 316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel for ≥500 psi
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating IP65
Electromagnetic rating CE compliant to EMC norm EN 61326:1997/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, over-voltage and short circuit protection
Shock 1,000 g’s according to IEC 60068-2-27
Vibration 20 g’s according to IEC 60068-2-6
Weight Approximately 3.5 oz.
 

WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Reviews

There are no reviews yet.

Be the first to review “NOSHOK 200-30-2-5-2-7-ST8 Pressure Transmitter, 0 psig to 30 psig, 0.25% Accuracy (BFSL), 0 Vdc to 10 Vdc Output, 1/4 NPT Male, Mini-Hirschmann, 0.8 mm SS Threaded Orifice Voltage Output Pressure Transducer”

Your email address will not be published. Required fields are marked *

Description

Pressure Transmitter, 0 psig to 30 psig, 0.25% Accuracy (BFSL), 0 Vdc to 10 Vdc Output, 1/4 NPT Male, Mini-Hirschmann, 0.8 mm SS Threaded Orifice

200 Series Voltage Output Pressure Transducers

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS
Output signals 0 Vdc to 5 Vdc, 3-wire; 0 Vdc to 10 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
1 Vdc to 6 Vdc, 3-wire; 1 Vdc to 11 Vdc, 3-wire
Pressure ranges Vacuum through 0 psig to 15,000 psig
Absolute from 0 psia to 15 psia through 0 psia to 300 psia
Accuracy ±0.5% full scale (BFSL); optional ±0.25% full scale (BFSL);
(Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale per year, non-accumulating
Adjustment ±10% full scale for zero and span
Response time ≤ 1 ms (between 10% and 90% full scale)
Pressure cycle limit ≤ 1 ms (between 10% and 90% full scale)
Service life > 100,000,000 load cycles
Temperature ranges Compensated 32 °F to 176 °F (0 °C to 80 °C)
Effect ±0.017% full scale/ °F for zero and span
Media -22 °F to 212 °F (-30 °C to 100 °C)
Ambient -40 °F to 185 °F (-40 °C to 85 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire,
1 Vdc to 6 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc, 3-wire)
Load limitations ≥ 5,000 Ω for 0 Vdc to 5 Vdc, 1 Vdc to 5 Vdc, and 1 Vdc to 6 Vdc outputs;
≥10,000 Ω for 0 Vdc to 10 Vdc and 1 Vdc to 11 Vdc outputs.
Current consumption 8 mA
Proof pressure 3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi
Burst pressure 3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
Measuring element 316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel for ≥500 psi
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating IP65
Electromagnetic rating CE compliant to EMC norm EN 61326:1997/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, over-voltage and short circuit protection
Shock 1,000 g’s according to IEC 60068-2-27
Vibration 20 g’s according to IEC 60068-2-6
Weight Approximately 3.5 oz.
 