NOSHOK 204-93-47/470 inH2O-1-1-28-TC Sanitary Pressure Transmitter
20 Series sanitary pressure transmitter is designed specifically for heavy-duty applications in the food and beverage industry where high accuracy, shock resistance and durability are required. The transmitter features pressure and temperature sensors mounted directly behind the diaphragm, which minimizes fill fluid, allows the use of a smaller diaphragm, and reduces the potential for damage. This provides active temperature compensation at the point of measurement to minimize temperature and position error. Diaphragms are laser-welded and helium leak-tested. In addition, turndown ratios up to 10:1 allow greater rangeability, minimizing required inventory.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | 204 | |||
PROCESS CONNECTIONS | 90 | E&H Universal adapter short version | 95 | King Gage Standard – 6″ |
91 | E&H Universal adapter long version | 96 | King Gage Long – 8″ | |
92 | Anderson Negele Type SL Short | 97 | Rosemount Tank Spud – 2″ | |
93 | Anderson Negele Type SL Long – 6″ | 98 | Rosemount Tank Spud – 6″ | |
94 | King Gage Short | 99 | Tank Mate Medium – 6″ | |
PRESSURE RANGES (Adjustable)* |
16/160 inH2O | 16 inH2O to 160 inH2O (.06 psig to 6 psig) | 6/58 psig | 6 psig to 58 psig (160 inH2O to 1,600 inH2O) |
47/470 inH2O | 47 inH2O to to 470 inH2O (1.7 psig to 17 psig) | |||
ACCURACIES | 1 | 0.1% of adjusted span | ||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 43 | 4 mA to 20 mA, 2-wire and Hart® signal |
ELECTRICAL CONNECTIONS | 25 | M12 x 1 (4-pin) | 71 | PG9 Cable Gland |
28 | 1/2” NPT Female | |||
OPTIONS | TC | Transparent Cover (for display) | 43 |
NOSHOK 204-93-47/470 inH2O-1-1-28-TC Sanitary Pressure Transmitter
20 Series sanitary pressure transmitter is designed specifically for heavy-duty applications in the food and beverage industry where high accuracy, shock resistance and durability are required. The transmitter features pressure and temperature sensors mounted directly behind the diaphragm, which minimizes fill fluid, allows the use of a smaller diaphragm, and reduces the potential for damage. This provides active temperature compensation at the point of measurement to minimize temperature and position error. Diaphragms are laser-welded and helium leak-tested. In addition, turndown ratios up to 10:1 allow greater rangeability, minimizing required inventory.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | 204 | |||
PROCESS CONNECTIONS | 90 | E&H Universal adapter short version | 95 | King Gage Standard – 6″ |
91 | E&H Universal adapter long version | 96 | King Gage Long – 8″ | |
92 | Anderson Negele Type SL Short | 97 | Rosemount Tank Spud – 2″ | |
93 | Anderson Negele Type SL Long – 6″ | 98 | Rosemount Tank Spud – 6″ | |
94 | King Gage Short | 99 | Tank Mate Medium – 6″ | |
PRESSURE RANGES (Adjustable)* |
16/160 inH2O | 16 inH2O to 160 inH2O (.06 psig to 6 psig) | 6/58 psig | 6 psig to 58 psig (160 inH2O to 1,600 inH2O) |
47/470 inH2O | 47 inH2O to to 470 inH2O (1.7 psig to 17 psig) | |||
ACCURACIES | 1 | 0.1% of adjusted span | ||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 43 | 4 mA to 20 mA, 2-wire and Hart® signal |
ELECTRICAL CONNECTIONS | 25 | M12 x 1 (4-pin) | 71 | PG9 Cable Gland |
28 | 1/2” NPT Female | |||
OPTIONS | TC | Transparent Cover (for display) | 43 |