-23%
$2,063.63 Original price was: $2,063.63.$1,597.52Current price is: $1,597.52.
Noshok 611-50inH2O-1-1-W-250-HT Small diameter submersible pressure transducer
Hydrostatic level measurement for use in applications including bore holes and wells with small diameters (outer diameter 0.87″)Low power output signals for battery-powered applications, and optional temperature output available5:1 turndown using optional HART? signal.316 Stainless Steel, PVDF and polyurethane wetted parts CE compliant to suppress RFI, EMI and ESD
611 | 611H | 318 LN/Hastelloy C-276 | ||||||
PRESSURE RANGES |
50 inH2O | 0 inH2O to 50 inH2O | 5 | 0 psig to 5 psig (11.5 ftH2O) | 50 | 0 psig to 50 psig (115 ftH2O) | ||
100 inH2O | 0 inH2O to 100 inH2O | 10 | 0 psig to 10 psig (23.1 ftH2O) | 100 | 0 psig to 100 psig (230.8 ftH2O) | |||
150 inH2O | 0 inH2O to 150 inH2O | 15 | 0 psig to 15 psig (34.6 ftH2O) | 25A | 0 psiq to 25 psia | |||
250 inH2O | 0 inH2O to 250 inH2O | 25 | 0 psig to 25 psig (57.7 ftH2O) | 50A | 0 psia to 50 psia | |||
100A | 0 psia to 100 psia | |||||||
psig = gauge pressure psia = absolute pressure Other ranges and measuring units available on request | ||||||||
ACCURACIES | 1 | ± 1.0 of span | 2 | ± 0.5% of span | ||||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 48 | 0.1 Vdc to 2.5 Vdc, 3 wire** | ||||
43 | 4 mA to 20 mA, 2-wire and HART® signal | 49 | 0.1 Vdc to 2.5 Vdc x 2 (pressure and temperature) *, ** | |||||
47 | 4 mA to 20 mA x 2 (pressure and temperature)* | |||||||
PROCESS CONNECTIONS |
N | Nosecone | W | Weighted nosecone | ||||
ELECTRICAL CONNECTIONS |
XX | Standard polyurethane (PUR) cable | 62-XX | Polyurethane (PUR) cable with 1/2″ NPT conduit connection | ||||
38-XX | Optional FEP cable | 63-XX | FEP cable with 1/2″ NPT conduit connection | |||||
NOTE: XX = length of cable in feet | ||||||||
OPTIONS | CBC | Cable Clamp | LP | Lightning Protection | JB | Cable Junction Box (NEMA 4X) | ||
HT | Increased media temperature (-40 °F to 176 °F) |
Noshok 611-50inH2O-1-1-W-250-HT Small diameter submersible pressure transducer
Hydrostatic level measurement for use in applications including bore holes and wells with small diameters (outer diameter 0.87″)Low power output signals for battery-powered applications, and optional temperature output available5:1 turndown using optional HART? signal.316 Stainless Steel, PVDF and polyurethane wetted parts CE compliant to suppress RFI, EMI and ESD
611 | 611H | 318 LN/Hastelloy C-276 | ||||||
PRESSURE RANGES |
50 inH2O | 0 inH2O to 50 inH2O | 5 | 0 psig to 5 psig (11.5 ftH2O) | 50 | 0 psig to 50 psig (115 ftH2O) | ||
100 inH2O | 0 inH2O to 100 inH2O | 10 | 0 psig to 10 psig (23.1 ftH2O) | 100 | 0 psig to 100 psig (230.8 ftH2O) | |||
150 inH2O | 0 inH2O to 150 inH2O | 15 | 0 psig to 15 psig (34.6 ftH2O) | 25A | 0 psiq to 25 psia | |||
250 inH2O | 0 inH2O to 250 inH2O | 25 | 0 psig to 25 psig (57.7 ftH2O) | 50A | 0 psia to 50 psia | |||
100A | 0 psia to 100 psia | |||||||
psig = gauge pressure psia = absolute pressure Other ranges and measuring units available on request | ||||||||
ACCURACIES | 1 | ± 1.0 of span | 2 | ± 0.5% of span | ||||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 48 | 0.1 Vdc to 2.5 Vdc, 3 wire** | ||||
43 | 4 mA to 20 mA, 2-wire and HART® signal | 49 | 0.1 Vdc to 2.5 Vdc x 2 (pressure and temperature) *, ** | |||||
47 | 4 mA to 20 mA x 2 (pressure and temperature)* | |||||||
PROCESS CONNECTIONS |
N | Nosecone | W | Weighted nosecone | ||||
ELECTRICAL CONNECTIONS |
XX | Standard polyurethane (PUR) cable | 62-XX | Polyurethane (PUR) cable with 1/2″ NPT conduit connection | ||||
38-XX | Optional FEP cable | 63-XX | FEP cable with 1/2″ NPT conduit connection | |||||
NOTE: XX = length of cable in feet | ||||||||
OPTIONS | CBC | Cable Clamp | LP | Lightning Protection | JB | Cable Junction Box (NEMA 4X) | ||
HT | Increased media temperature (-40 °F to 176 °F) |
No account yet?
Create an Account
Reviews
There are no reviews yet.