Noshok 623-200-1-1-8-6-ST8 Non-Incendive Pressure Transmitters

Part Number: 623-200-1-1-8-6-ST8 Tag:

Original price was: $650.49.Current price is: $520.39.

20 People watching this product now!

Noshok 623-200-1-1-8-6-ST8 Non-Incendive Pressure Transmitters

Vacuum and compound ranges through 0 psig to 15,000 psig; absolute ranges from 0 psia to 15 psia through 0 psia to 100 psia Current and voltage outputs available 316 stainless steel and Elgiloy wetted parts Factory Mutual and Canadian Standards Association approved CE compliant to suppress RFI, EMI and ESD NACE MR0175/ISO 15156 compliant NSI/ISA-12.27.01-2003 approved single seal

SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc low power, 3-wire; 0.5 Vdc to 4.5 Vdc low power, 3-wire
Pressure ranges Vacuum through 0 psig to 15,000 psig
Absolute through 0 psia to 100 psia
Accuracy ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis,
non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale for 1 year, non-accumulating
Response time ≤1 ms (between 10% and 90% full scale)
Service life >100,000,000 load cycles
Temperature ranges Compensated 32 °F to 176 °F (0 °C to 80 °C)
Zero effect is ±0.011% full scale/ °F within compensated range
Span effect is ±0.011% full scale/ °F within compensated range
Media -40 °F to 212 °F (-40 to 100 °C)
Ambient -22 °F to 176 °F (-30 °C to 80 °C)
Storage -22 °F to 212 °F (-30 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)
6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire)
Load limitations ≤ (VPower -10)/0.020 Amp for 4 mA to 20 mA; ≥ 10,000 Ω for 1 Vdc to 5 Vdc, 3-wire
Proof pressure 3 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi range
Burst pressure 3.8 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
Measuring element 623 Series is 316 stainless steel for ranges up through 0 psi to 300 psi,
316 stainless steel and Elgiloy for ranges 0 psig to 500 psig and higher;
624 Series is 316 stainless steel with NBR o-ring; FKM o-ring optional
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating I65 to IP67 dependent upon electrical connection
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, over-voltage and short circuit protected
Shock 1000 g’s according to IEC 60068-2-27
Vibration 20 g’s according to IEC 60068-2-6
Weight Approximately 12 oz.

Reviews

There are no reviews yet.

Be the first to review “Noshok 623-200-1-1-8-6-ST8 Non-Incendive Pressure Transmitters”

Your email address will not be published. Required fields are marked *

Description

Noshok 623-200-1-1-8-6-ST8 Non-Incendive Pressure Transmitters

Vacuum and compound ranges through 0 psig to 15,000 psig; absolute ranges from 0 psia to 15 psia through 0 psia to 100 psia Current and voltage outputs available 316 stainless steel and Elgiloy wetted parts Factory Mutual and Canadian Standards Association approved CE compliant to suppress RFI, EMI and ESD NACE MR0175/ISO 15156 compliant NSI/ISA-12.27.01-2003 approved single seal

SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc low power, 3-wire; 0.5 Vdc to 4.5 Vdc low power, 3-wire
Pressure ranges Vacuum through 0 psig to 15,000 psig
Absolute through 0 psia to 100 psia
Accuracy ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis,
non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale for 1 year, non-accumulating
Response time ≤1 ms (between 10% and 90% full scale)
Service life >100,000,000 load cycles
Temperature ranges Compensated 32 °F to 176 °F (0 °C to 80 °C)
Zero effect is ±0.011% full scale/ °F within compensated range
Span effect is ±0.011% full scale/ °F within compensated range
Media -40 °F to 212 °F (-40 to 100 °C)
Ambient -22 °F to 176 °F (-30 °C to 80 °C)
Storage -22 °F to 212 °F (-30 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)
6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire)
Load limitations ≤ (VPower -10)/0.020 Amp for 4 mA to 20 mA; ≥ 10,000 Ω for 1 Vdc to 5 Vdc, 3-wire
Proof pressure 3 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi range
Burst pressure 3.8 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
Measuring element 623 Series is 316 stainless steel for ranges up through 0 psi to 300 psi,
316 stainless steel and Elgiloy for ranges 0 psig to 500 psig and higher;
624 Series is 316 stainless steel with NBR o-ring; FKM o-ring optional
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating I65 to IP67 dependent upon electrical connection
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, over-voltage and short circuit protected
Shock 1000 g’s according to IEC 60068-2-27
Vibration 20 g’s according to IEC 60068-2-6
Weight Approximately 12 oz.